12.8-100
UGA POWER
85076000
>Specification
No. |
Item |
General Parameter |
Remark |
|
1 |
Combination method |
4S1P |
||
2 |
Rated Capacity |
Typical |
100Ah |
Standard discharge after Standard charge(package) |
Minimum |
100Ah |
|||
3 |
Factory Voltage |
12.8V~13.2V |
Mean Operation Voltage |
|
4 |
Internal Impedance |
≤50mΩ |
Under 20±5℃ Environment Temperature , the Usage Frequency of Fully Charge( 1KHz) , Use AC Internal Impedance test machine to test 20±5℃. |
|
5 |
Max Charging Current(Icm) |
50.0A |
Ampere-meter ,Maximum allowable charging current of the battery pack. |
|
6 |
Limited Charging Voltage(Ucl) |
14.6V |
Volta-meter(Serial*3.65V) ,Battery pack safe charging voltage |
|
7 |
Max Discharging current |
100.0A |
Maximum discharge current allowed by the battery pack. |
|
8 |
Discharge Cut-off voltage(Udo) |
10.0V |
Voltage of the battery when the discharge is stopped. |
|
9 |
Operation Temperature Range |
Charge:0~45℃ |
||
Discharge: -20~60℃ |
||||
10 |
Storage Temperature Range |
-20℃~45℃ |
Recommend(25±3℃); ≤90%RH storage moisture range. |
|
11 |
Full Weight |
11.3kg±0.1Kg |
Include case |
|
12 |
Cycle Performance |
2000 cycles |
≥80%Nominal Capacity |
|
If stored for a long time(don't used,exceed three months), the cell should be stored in drying and cooling place. The cell's storage voltage should be 12.8V~13.2V and the cell is to be stored in a condition that the temperature of 23±2℃ and the humidity 0f 45%- 75%. Long-term use of unused batteries to recharge every 3 months.Ensure that the battery voltage is within the above range.
>Application of Lithium Storage Battery
◆ UPS backup power;
◆ Solar system/wind system;
◆ Golf cart;
◆ Electric two wheeler,three-wheeler,low speed vehicle;
◆ Solar street lamp,lawn lamp and other light system

>Specification
No. |
Item |
General Parameter |
Remark |
|
1 |
Combination method |
4S1P |
||
2 |
Rated Capacity |
Typical |
100Ah |
Standard discharge after Standard charge(package) |
Minimum |
100Ah |
|||
3 |
Factory Voltage |
12.8V~13.2V |
Mean Operation Voltage |
|
4 |
Internal Impedance |
≤50mΩ |
Under 20±5℃ Environment Temperature , the Usage Frequency of Fully Charge( 1KHz) , Use AC Internal Impedance test machine to test 20±5℃. |
|
5 |
Max Charging Current(Icm) |
50.0A |
Ampere-meter ,Maximum allowable charging current of the battery pack. |
|
6 |
Limited Charging Voltage(Ucl) |
14.6V |
Volta-meter(Serial*3.65V) ,Battery pack safe charging voltage |
|
7 |
Max Discharging current |
100.0A |
Maximum discharge current allowed by the battery pack. |
|
8 |
Discharge Cut-off voltage(Udo) |
10.0V |
Voltage of the battery when the discharge is stopped. |
|
9 |
Operation Temperature Range |
Charge:0~45℃ |
||
Discharge: -20~60℃ |
||||
10 |
Storage Temperature Range |
-20℃~45℃ |
Recommend(25±3℃); ≤90%RH storage moisture range. |
|
11 |
Full Weight |
11.3kg±0.1Kg |
Include case |
|
12 |
Cycle Performance |
2000 cycles |
≥80%Nominal Capacity |
|
If stored for a long time(don't used,exceed three months), the cell should be stored in drying and cooling place. The cell's storage voltage should be 12.8V~13.2V and the cell is to be stored in a condition that the temperature of 23±2℃ and the humidity 0f 45%- 75%. Long-term use of unused batteries to recharge every 3 months.Ensure that the battery voltage is within the above range.
>Application of Lithium Storage Battery
◆ UPS backup power;
◆ Solar system/wind system;
◆ Golf cart;
◆ Electric two wheeler,three-wheeler,low speed vehicle;
◆ Solar street lamp,lawn lamp and other light system