12.8-100
UGA POWER
85076000
>Specification
No. | Item | General Parameter | Remark | |
1 | Combination method | 4S1P | ||
2 | Rated Capacity | Typical | 100Ah | Standard discharge after Standard charge(package) |
Minimum | 100Ah | |||
3 | Factory Voltage | 12.8V~13.2V | Mean Operation Voltage | |
4 | Internal Impedance | ≤50mΩ | Under 20±5℃ Environment Temperature , the Usage Frequency of Fully Charge( 1KHz) , Use AC Internal Impedance test machine to test 20±5℃. | |
5 | Max Charging Current(Icm) | 50.0A | Ampere-meter ,Maximum allowable charging current of the battery pack. | |
6 | Limited Charging Voltage(Ucl) | 14.6V | Volta-meter(Serial*3.65V) ,Battery pack safe charging voltage | |
7 | Max Discharging current | 100.0A | Maximum discharge current allowed by the battery pack. | |
8 | Discharge Cut-off voltage(Udo) | 10.0V | Voltage of the battery when the discharge is stopped. | |
9 | Operation Temperature Range | Charge:0~45℃ | ||
Discharge: -20~60℃ | ||||
10 | Storage Temperature Range | -20℃~45℃ | Recommend(25±3℃); ≤90%RH storage moisture range. | |
11 | Full Weight | 11.3kg±0.1Kg | Include case | |
12 | Cycle Performance | 2000 cycles | ≥80%Nominal Capacity |
If stored for a long time(don't used,exceed three months), the cell should be stored in drying and cooling place. The cell's storage voltage should be 12.8V~13.2V and the cell is to be stored in a condition that the temperature of 23±2℃ and the humidity 0f 45%- 75%. Long-term use of unused batteries to recharge every 3 months.Ensure that the battery voltage is within the above range.
>Application of Lithium Storage Battery
◆ UPS backup power;
◆ Solar system/wind system;
◆ Golf cart;
◆ Electric two wheeler,three-wheeler,low speed vehicle;
◆ Solar street lamp,lawn lamp and other light system
>Specification
No. | Item | General Parameter | Remark | |
1 | Combination method | 4S1P | ||
2 | Rated Capacity | Typical | 100Ah | Standard discharge after Standard charge(package) |
Minimum | 100Ah | |||
3 | Factory Voltage | 12.8V~13.2V | Mean Operation Voltage | |
4 | Internal Impedance | ≤50mΩ | Under 20±5℃ Environment Temperature , the Usage Frequency of Fully Charge( 1KHz) , Use AC Internal Impedance test machine to test 20±5℃. | |
5 | Max Charging Current(Icm) | 50.0A | Ampere-meter ,Maximum allowable charging current of the battery pack. | |
6 | Limited Charging Voltage(Ucl) | 14.6V | Volta-meter(Serial*3.65V) ,Battery pack safe charging voltage | |
7 | Max Discharging current | 100.0A | Maximum discharge current allowed by the battery pack. | |
8 | Discharge Cut-off voltage(Udo) | 10.0V | Voltage of the battery when the discharge is stopped. | |
9 | Operation Temperature Range | Charge:0~45℃ | ||
Discharge: -20~60℃ | ||||
10 | Storage Temperature Range | -20℃~45℃ | Recommend(25±3℃); ≤90%RH storage moisture range. | |
11 | Full Weight | 11.3kg±0.1Kg | Include case | |
12 | Cycle Performance | 2000 cycles | ≥80%Nominal Capacity |
If stored for a long time(don't used,exceed three months), the cell should be stored in drying and cooling place. The cell's storage voltage should be 12.8V~13.2V and the cell is to be stored in a condition that the temperature of 23±2℃ and the humidity 0f 45%- 75%. Long-term use of unused batteries to recharge every 3 months.Ensure that the battery voltage is within the above range.
>Application of Lithium Storage Battery
◆ UPS backup power;
◆ Solar system/wind system;
◆ Golf cart;
◆ Electric two wheeler,three-wheeler,low speed vehicle;
◆ Solar street lamp,lawn lamp and other light system