FOBERRIA 12v100 Ups Agm sealed Lead Acid Battery

Model:FBR12-100
Voltage:12V
Capacity:100Ah
Dimension:330*171*214(220)
MOQ:10PC
Availability:
Quantity:
  • FBR12-100

  • FOBERRIA

  • 85072000

Product Overview

The FOBERRIA FBR12-100 is a 12V sealed lead acid AGM battery for UPS backup power. Its 100Ah rating is measured at the 20-hour rate. Defined charging limits, F14 terminals and a compact case support detailed battery replacement assessment.

FOBERRIA FBR12-100 12V 100Ah AGM battery

UPS Battery Selection Starts with Discharge Rate

A capacity label alone does not establish UPS autonomy. FBR12-100 provides separate ratings for 20-hour, 10-hour and one-hour discharge. Buyers should compare the required load duration with the matching rating before choosing a battery quantity.

100[1].png

Technical Specifications

FBR12-100 specification

Parameter

Condition / detail

Value

Battery Model No.

—

FBR12-100

Nominal Voltage

—

12V

Capacity(25ºC)

20HR(10.5V)

100Ah

Capacity(25ºC)

10HR(10.5V)

85Ah

Capacity(25ºC)

1HR(9.6V)

60Ah

Dimension

Length

330±1mm

Dimension

Width

171±1mm

Dimension

Height

214±1mm

Dimension

Total height

220±1mm

Approx. Weight

—

29.5kg ±5%

Terminal type

—

F14

Internal resistance(Fully charged,25ºC)

—

Approx. 4.5mΩ

Capacity affected by temperature(20HR)

40ºC

102%

Capacity affected by temperature(20HR)

25ºC

100%

Capacity affected by temperature(20HR)

0ºC

85%

Capacity affected by temperature(20HR)

-15ºC

65%

Self-discharge(25ºC)

3month

Remaining Capacity:91%

Self-discharge(25ºC)

6month

Remaining Capacity:82%

Self-discharge(25ºC)

12month

Remaining Capacity:65%

Nominal operating temperature

—

25ºC±3ºC(77ºF±5ºF)

Operating temperature range

Discharge

-15ºC-50ºC(5ºF-122ºF)

Operating temperature range

Charge

-10ºC-50ºC(14ºF-122ºF)

Operating temperature range

Storage

-20ºC-50ºC(-4ºF-122ºF)

Float charging voltage(25ºC)

—

13.6 to 13.8V(Temperature compensation:-18mV/ºC)

Cyclic charging voltage(25ºC)

—

14.5 to 15V(Temperature compensation:-30mV/ºC)

Max charging current

—

30A

Max discharging current

—

800A(5sec.)

Designed floating life(20ºC)

—

12years

How the Capacity Ratings Affect Backup Planning

At 25°C, the battery delivers 100Ah over 20 hours to 10.5V, or 85Ah over 10 hours to 10.5V. The one-hour entry is 60Ah to 9.6V. These different test conditions should remain attached to the capacity figures during comparison.

Case Dimensions and F14 Connections

The case measures 330 ±1mm long, 171 ±1mm wide and 214 ±1mm high. Total height reaches 220 ±1mm. Allow space for the installed connections as well as the case. Approximate mass is 29.5kg ±5%; the terminal designation is F14.

Float Charging for Standby Duty

At 25°C, the specified float range is 13.6–13.8V, with temperature compensation of −18mV/°C. This is the relevant charging entry for standby assessment. Charger settings should be checked against the complete battery arrangement and its operating temperature.

Cyclic Charging and Current Limits

The cyclic charge specification is 14.5–15V at 25°C, with −30mV/°C compensation. Maximum charging current is 30A. The separate 800A discharge figure applies for five seconds; it does not describe sustained backup output.

Temperature and Available Capacity

The 20-hour capacity reference falls to 85% at 0°C and 65% at −15°C. It is 100% at 25°C and 102% at 40°C. Backup sizing should therefore include the battery-room temperature, rather than applying the room-temperature rating everywhere.

Storage Retention and Float Design Life

Remaining capacity at 25°C is listed as 91% after three months, 82% after six months and 65% after twelve months. Designed floating life is 12 years at 20°C. This design reference is separate from a warranty or a promised replacement interval.

Application Fit within the UPS Range

This model belongs to the FOBERRIA VRLA UPS battery range. For an existing UPS, record the DC bus voltage, installed battery count and required backup duration. A matching nominal voltage alone is insufficient to establish a replacement configuration.

Battery plate processing equipment shown on the FOBERRIA product website

Frequently Asked Questions

What does the 100Ah rating mean for this AGM UPS battery?

FBR12-100 is rated 100Ah at 25°C over 20 hours to 10.5V. It is not a guarantee of 100Ah at every discharge speed; its one-hour rating is 60Ah to 9.6V.

What float voltage does the 12V 100Ah AGM battery require?

The FBR12-100 float specification is 13.6–13.8V at 25°C. The stated temperature compensation is −18mV/°C, so charger review must include battery temperature.

Can the AGM UPS battery supply 800A continuously?

No. The FBR12-100 table gives 800A for five seconds only. Sustained UPS sizing requires load and discharge information beyond this short-duration limit.

Will FBR12-100 fit a 214mm-high compartment?

The case height is 214 ±1mm, but overall height is 220 ±1mm. Check the compartment against total height and the installed F14 connection arrangement.

How does cold operation affect this AGM UPS battery?

At the 20-hour rate, capacity is listed as 85% at 0°C and 65% at −15°C. Use the expected battery temperature when assessing the backup requirement.

Is the 12-year floating life a warranty?

The table specifies a 12-year designed floating life at 20°C for FBR12-100. It does not define a 12-year warranty; commercial warranty terms require separate confirmation.