12V150ah VRLA smf battery Lead Acid AGM Industrial Storage Battery

Model:FBR12-150
Voltage:12V
Capacity:150Ah
Dimension:485*172*240(240)
MOQ:10PC
Availability:
Quantity:
  • FBR12-150

  • FOBERRIA

  • 8507200000

Product Overview

FOBERRIA FBR12-150 is a 12V 150Ah VRLA AGM battery for industrial storage and solar power requirements. Its 485 × 172 × 240mm case, F13 terminals and 45A maximum charging current provide practical reference points for installation planning.

FOBERRIA FBR12-150 industrial lead acid battery

Industrial Storage Requirements

The FBR12-150 combines a 150Ah capacity designation with a 12V nominal voltage. For an industrial storage project, identify whether the battery will remain on standby or undergo regular cycling. This determines which published charging entry needs closer review.

FBR12-150 Technical Data

FBR12-150 specification

Parameter

Condition / detail

Value

Battery Model No.

—

FBR12-150

Nominal Voltage

—

12V

Capacity(25ºC)

20HR(5.25V)

150Ah

Capacity(25ºC)

10HR(5.25V)

127Ah

Capacity(25ºC)

1HR(4.80V)

90Ah

Dimension

Length

485±2mm

Dimension

Width

172±2mm

Dimension

Height

240±2mm

Dimension

Total height

240±2mm

Approx. Weight

—

43kg±4%

Terminal type

—

F13

Internal resistance(Fully charged,25ºC)

—

Approx 3.5mΩ

Capacity affected by temperature(20HR)

40ºC

102%

Capacity affected by temperature(20HR)

25ºC

100%

Capacity affected by temperature(20HR)

0ºC

85%

Capacity affected by temperature(20HR)

-15ºC

65%

Self-discharge(25ºC)

3month

Remaining Capacity:91%

Self-discharge(25ºC)

6month

Remaining Capacity:82%

Self-discharge(25ºC)

12month

Remaining Capacity:65%

Nominal operating temperature

—

25ºC±3ºC(77ºF±5ºF)

Operating temperature range

Discharge

-15ºC-50ºC(5ºF-122ºF)

Operating temperature range

Charge

-10ºC-50ºC(14ºF-122ºF)

Operating temperature range

Storage

-20ºC-50ºC(-4ºF-122ºF)

Float charging voltage(25ºC)

—

13.5 to 13.8V(Temperature compensation:-18mV/ºC)

Cyclic charging voltage(25ºC)

—

14.5 to 15V(Temperature compensation:-30mV/ºC)

Max charging current

—

45A

Max discharging current

—

1200A(5sec.)

Designed floating life(20ºC)

—

12years

Selection note: Capacity cutoff voltages are reproduced exactly from the supplier table: 5.25V for 20HR/10HR and 4.80V for 1HR. They require confirmation for this nominal 12V model and must not be used as charger/controller settings.

Capacity Test Conditions to Resolve

The published capacities are 150Ah at 20HR, 127Ah at 10HR and 90Ah at 1HR, all at 25°C. The accompanying cutoff entries need supplier confirmation before runtime calculations. Request a model-specific discharge sheet for the intended load and final voltage.

Tray Space, Weight and Terminal Access

Length is 485 ±2mm and width is 172 ±2mm. Both case height and total height are 240 ±2mm. Approximate weight is 43kg ±4%. A tray review should include the supporting structure, handling access and the actual F13 terminal arrangement.

Float Voltage for the Installation

The FBR12-150 float range is 13.5–13.8V at 25°C. Its temperature-compensation value is −18mV/°C. Record the charger’s available settings and temperature-sensing arrangement when submitting a battery-bank enquiry.

Cyclic Recharge and Maximum Input Current

For cyclic charging, the table gives 14.5–15V at 25°C and −30mV/°C compensation. Charging current must remain within the published 45A maximum. These values describe the battery; the complete bank configuration still needs charger coordination.

Short Pulse Current and Resistance

The 1200A discharge limit is specified for five seconds. Fully charged internal resistance at 25°C is approximately 3.5mΩ. Neither entry establishes a sustained industrial load rating, so longer discharge requirements need the appropriate performance data.

Ambient Conditions for Capacity Assessment

The reference operating temperature is 25 ±3°C. At the 20-hour rate, listed capacity becomes 85% at 0°C and 65% at −15°C. Discharge, charge and storage have separate allowable temperature windows, retained in the technical table.

Storage Losses and Planned Service

At 25°C, remaining capacity is 91%, 82% and 65% after three, six and twelve months respectively. Designed float life is 12 years at 20°C. Procurement schedules should account for storage duration and request the applicable commissioning instructions.

Solar Storage and Supplier Coordination

The product is described for solar and industrial storage and sits within the VRLA UPS battery catalogue. The company introduction outlines FOBERRIA’s battery portfolio. Submit the installation dimensions, intended duty and required discharge endpoint through the supplier contact page for FBR12-150-specific clarification.

Battery connection work shown in the FOBERRIA company profile

Frequently Asked Questions

What capacity figures are published for the 150Ah VRLA battery?

FBR12-150 lists 150Ah at 20HR, 127Ah at 10HR and 90Ah at 1HR at 25°C. The source cutoff-voltage entries require confirmation before these figures are used in runtime calculations.

What float voltage is specified for the 150Ah VRLA battery?

At 25°C, FBR12-150 specifies 13.5–13.8V for float charging, with −18mV/°C temperature compensation. Review the charger against this model-specific range.

Can the 150Ah VRLA battery discharge at 1200A continuously?

No. FBR12-150 lists 1200A for five seconds. A sustained-load assessment needs discharge data for the required duration and cutoff voltage.

What are the FBR12-150 dimensions and weight?

The listed dimensions are 485 ±2 × 172 ±2 × 240 ±2mm, with total height also 240 ±2mm. Approximate mass is 43kg ±4%, and the connection type is F13.

What is the maximum charging current for this 150Ah AGM battery?

The maximum is 45A. The cyclic voltage range is 14.5–15V at 25°C; use the appropriate charge regime and temperature conditions for the installation.

Does the 12-year design figure apply at any temperature?

FBR12-150 gives 12 years as designed floating life specifically at 20°C. The figure should retain that condition and should not be converted into a warranty claim.